High-Fouling Slurry Service Standard

Spiral Heat Exchangers (SHE) NDT Guide

Authoritative engineering guide for Type 1 counter-current and Type 2 cross-flow Spiral Heat Exchangers. Inspect concentric curved plate channels, slurry erosion, circumferential edge welds, and cover gasket seals.

SHE ArchitectureSingle-Pass Flow
Self-Cleaning Concentric Channels

Single curved channel flow increases local velocity at deposits, creating a continuous self-cleaning effect in pulp, paper, and wastewater service.

Spiral Heat Exchanger Design Classifications

Engineered with two concentric metal sheets wrapped around a central manifold core.

Full Counter-Current Flow

Type 1 Spiral Exchanger

Features two continuous curved spiral channels wrapped concentrically. Fluid flows in true counter-current, creating a single-path self-cleaning flow effect ideal for heavy slurries, wastewater, and fouling fluids.

NDT Inspection Focus:

Channel wall thickness measurements via UT, spiral edge seal weld penetrant testing (PT), and cover gasket seating area inspection.

Cross-Flow Condenser

Type 2 Spiral Exchanger

One fluid flows spirally in a closed channel, while the second vapor or gas stream flows cross-wise through the open spiral core. Widely used as overhead condensers and reboilers in distillation columns.

NDT Inspection Focus:

Vapor entrance zone erosion sizing, condensate outlet nozzle weld UT/RT, and shell-to-spiral plate attachment weld inspection.

Zero-Commission B2B Platform

How B2B Project Workflow Works

From initial RFP scope to direct client sign-off. NDT EXCHANGE does not charge commissions or manage project payments.

01

RFP Scope

Asset Owner Scope

Asset Owner posts turnkey B2B inspection scope with technical specifications, asset list, and required NDT methods.

02

Competitive Bids

Agency Proposals

Certified NDT agencies submit competitive proposals (Fixed-Bid / T&M) detailing technician rosters and day rates.

03

Direct Settlement / Escrow

Payment Security

Client awards bid and sets up direct milestone payment or escrow — NDT EXCHANGE never holds or manages project funds.

04

Field Execution

Testing & Calibration

Level II/III inspectors perform on-site testing (PAUT, TOFD, MFL, UT), capturing flaw data and calibration overlays.

05

Sign-Off & Payout

Audit & Settlement

Level III auditor reviews findings; upon client sign-off, funds release directly to agency with 0% platform commission.

Project Data Flow:1. RFP Scope2. Agency Bids3. Direct Settlement4. Field Execution5. Direct Sign-Off
💡 Payment Policy: NDT EXCHANGE charges 0% fees and never holds or handles project funds.