ASME B31.3 Piping Isometric Designer ASME B31.3 / API 570 30° Axonometric CAD Designer
Symbol Palette
39 SymbolsPiping Line Specification
Quick Route Segment
Standard Spool Presets
ASME B31.3 Isometric CAD & 3D Volumetric Pressure Engine
Explore how NDT Exchange unites 2D 30° isometric spool routing, 4-quadrant clock-face ultrasonic thickness rings, 3D volumetric hoop stress & MAWP visualization, and API 570 remaining-life compliance in one desktop-class workspace.
6-Axis Isometric Spool Routing, Branching & 4-Class P&ID Symbol Palette
Route 3D process piping loops along standardized 30° isometric axes (+X East, −X West, +Y North, −Y South, +Z Up, −Z Down) with automatic elevation drop shadows and 4-quadrant camera rotation (NE, NW, SW, SE). Drag and drop from 28+ standardized symbols spanning Pipe & Fittings, Valves, Process Instruments (TW, FE, PI, Injection Quills), and Equipment Nozzle Tie-Ins (Pump, Vessel, Exchanger, Tank).
Complete ASME B31.3, API 570 & 3D Pressure Capabilities Matrix
Engineered for Process Piping Designers, API 570 Authorized Piping Inspectors, and Turnaround Integrity Teams. Every thickness retirement calculation, Lorentz elbow factor, and B31G burst assessment runs natively in your browser with full Metric & Imperial accuracy.
6-Axis 30° Isometric Routing
- +X East, −X West, +Y North, −Y South, +Z Up, −Z Down
- 4-Quadrant Isometric Camera Rotation (NE, NW, SW, SE)
- Interactive Branching From Tees & Mid-Spool Splitting
- 3D Isometric Tape Measure (ΔX, ΔY, ΔZ & True Vector Length)
28+ P&ID & Isometric Symbols
- Spools, 90°/45° Elbows, Tees, Concentric/Eccentric Reducers
- Gate, Globe, Ball, Check, OS&Y, PRV & Motorized Valves
- Thermowells (TW), Orifice Plates (FE), Injection Quills (IJQ)
- Pump (P-101), Vessel (V-101), Exchanger & Tank Nozzle Tie-Ins
2D & 3D Volumetric Pressure Engine
- ASME B31.3 Sec 304.1.2 Pressure Design Wall (t_min) & MAWP
- Sec 304.2.1 Lorentz Elbow Intrados Stress Factor (I = 1.25)
- 3D Orbiting Cylinders Colored by Hoop Stress (σ_h) or Fluid ΔP
- Hydrostatic Elevation Head & Control Valve Pressure Drop
2D Polar Clock-Face UT Ring
- 4-Quadrant Readings: 12:00, 3:00 (Extrados), 6:00, 9:00 (Intrados)
- Visual Red Dashed t_min Retirement Ring & Pressurized Bore
- Automatic Governing Minimum Wall Extraction Across Quadrants
- Live Hoop Stress (PSI/MPa) & Corroded MAWP KPI Strip
API 570 CML & B31G Defect Logging
- Pin Localized Defects (FAC, CUI, MIC Pitting, Girth Weld Cracks)
- ASME B31G / API 579 Folias Bulging Factor (M_t) & Burst Pressure
- API 570 Sec 7 Corrosion Rate, Remaining Life & Half-Life Interval
- Bi-Directional Sync with Bottom Discrepancy & Defect Console
Weld Register & Outage Compare
- Track Butt (BW), Socket (SW) & Fillet (FW) Weld IDs
- Shop, Field & Golden Tie-In Joint Categorization + NDE Status
- Multi-Temporal Outage Compare Mode (Δt & mm/yr Drift)
- 1-Click Deep Link to PAUT Weld Scan Plan Ray Tracer
AutoCAD DXF, BOM & Level III Reports
- Bi-Directional AutoCAD (.dxf) Spool & CML Import/Export
- Automated 4-Class Bill of Materials (.csv) Pipe Cut-Sheet
- Landscape Vector .svg Blueprint with ASME Title Block
- Certified API 570 Level II/III Inspection Report PDF
Simulate Scenarios & Cloud Vault
- 1-Click Outage Simulations (FAC Elbow, Dead-Leg MIC, CUI Saddle)
- Standard Spool Presets (Pump Discharge, Control Valve Bypass)
- ASME B36.10M / B36.19M Pipe Schedule & Material Database
- Auto-Saving Browser Local Vault + Organization Cloud Sync
Governing ASME B31.3 & API 570 Equations Built Into The Solver
| Engineering Solver | Code Clause | Formula & Enforcement |
|---|---|---|
| Straight Pipe Design Wall (t_m) | ASME B31.3 §304.1.2 | t_m = (P · D) / (2 · (S · E · W + P · Y)) + c |
| Elbow Intrados Lorentz Factor (I) | ASME B31.3 §304.2.1 | I = (4(R_1/D) − 1) / (4(R_1/D) − 2) = 1.25 for LR |
| Folias Bulging Factor (M_t) | ASME B31G / API 579 | M_t = √(1 + 0.6275(L²/Dt) − 0.003375(L²/Dt)²) |
| Remaining Life & Half-Life | API 570 §7.1 / §7.2 | RL = (t_actual − t_min) / CR; Interval ≤ 0.5 × RL |
| Injection Point Mix Zone | API 570 §5.5.3 | 12" upstream to 2nd change of direction or 25 ft downstream |
1. How do I inspect pipe pressure in 2D vs. 3D?
In 2D Iso, click MAWP Stress on the canvas bar or inspect the 2D Polar Clock-Face Ring (12/3/6/9 o'clock) in the right panel. Click 3D View in the top ribbon (or 3D Pressure) to orbit the 3D volumetric cylinders colored by Hoop Stress (σ_h), Fluid Pressure (ΔP), or B31.3 MAWP margin.
2. Why does a 90° elbow show higher hoop stress than straight pipe?
Per ASME B31.3 Sec 304.2.1, toroidal curvature concentrates circumferential membrane stress on the inside bend (intrados) by the Lorentz factor I = 1.25 (+25% stress on a 1.5D Long-Radius elbow), while fluid turbulence erodes the outer bend (extrados).
3. How do I generate an API 570 inspection report or BOM?
Use Export → ASME B31.3 BOM Cut-Sheet (.csv) for pipe/fitting quantities, or switch to Report Deliverable to preview and sign off the certified API 570 inspection dossier.
Process Piping Ultrasonic Gauges, Corrosion Scanners & Pulsed Eddy Current Systems
Field-proven UT thickness gauges, PAUT weld scanners, and CUI PEC arrays for API 570 piping integrity
The industry-leading ultra-high-temperature ultrasonic couplant engineered for on-stream thickness gauging, corrosion monitoring, and PAUT scans without plant shutdowns. Conforms strictly to ASME Section V Article 4 T-433 halogen and sulfur purity requirements (<50 ppm).
Economical, multi-temperature silicone-based couplant with outstanding acoustic impedance for on-stream refinery pipe scanning, boiler tubes, and process vessels under API 570 inspection programs.
The premier environmentally benign, bio-based ultrasonic couplant formulated specifically to prevent stress corrosion cracking (SCC) on titanium, inconel, and austenitic stainless steels. Complete acoustic transparency with rapid clean-off.
Process Piping NDT Procedures & Code Standards
Field procedures for API 570 CML ultrasonic thickness surveys, ASME B31.3 t-min calculations, and CUI screening
Pulsed Eddy Current (PEC) Wall Loss Sizing Guide
Technical procedure for Pulsed Eddy Current (PEC) screening of remaining wall thickness through thermal insulation, fireproofing, and aluminum/stainless weather jackets.
Process Piping Ultrasonic CML Thickness & High-Temp Sizing Guide
Authoritative field procedure for precision ultrasonic thickness measurements at Condition Monitoring Locations (CMLs), high-temperature acoustic velocity temperature compensation, and ASME B31.3 t-min calculations.
Digital Radiography (CR & DDA) Image Quality & Flaw Sizing Guide
Technical guide for Computed Radiography (CR) and Digital Detector Array (DDA) inspection of welded joints, image quality indicator (IQI) sensitivity verification, SNR normalization, and geometric unsharpness limits.
Ratings & Field Evaluations
Strictly authenticated engineering reviews from Level II/III certified specialists, plant operators, and NDT service leaders.
Field verified under applicable ASME, API, AWS, and ISO governing codes.
No Verified Evaluations Yet
Be the first certified Level II/III inspector, OEM specialist, or plant reliability lead to evaluate ASME B31.3 Piping Isometric Studio.
Technical guides, CAD geometries, code calculators, and flaw criteria are engineered in accordance with active industry standards (ASME BPVC, API, AWS, ISO) under ASNT / ISO 9712 Level III engineering guidance for preliminary technical evaluation. This does not replace certified Level III, Professional Engineer (PE), or API 510/570/653 field sign-offs. Always verify specific job parameters against governing client specifications and active code editions before field execution.
All product, brand, and company names (e.g. Olympus, Evident, OmniScan, Sonatest, WAVE, Veo, Eddyfi, Gekko, Mantis, Waygate Technologies, Krautkrämer, Mentor UT, Zetec, UltraVision, BeamTool, Eclipse Scientific, ASME, API, AWS, ISO) are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with, sponsorship, or endorsement by them. All brand and format references are used strictly in a nominative capacity to identify hardware compatibility, scan plan data interchange, and engineering standards compliance.