Acoustic Physics • ASME Section VShear Wave Angle Beam

Snell's Law Ultrasonic Calculator & Acoustic Ray Tracer

Compute 1st and 2nd critical angles, refracted longitudinal and shear wave beam angles, half-skip, and full V-path bounce coordinates in carbon steel, stainless steel, and aluminum test specimens.

1. Acoustic Media & Transducer SetupShear Wave Only
Wedge Velocity V1V_1:2330 m/s
VsV_s (Shear): 3240 m/sVlV_l (Long): 5920 m/s
36.0°
Normal (0°)1st Crit: 23.2°2nd Crit: 46.0°
Typical steel plate / pipe wall
Mode Analysis:Between 1st and 2nd Critical Angle (Optimal): Longitudinal mode is eliminated; pure shear wave enters steel.
2. Acoustic Ray Tracing & V-Path Scale CADθ_shear = 54.8°
Refracted Shear54.8°
Half Skip35.5 mm
Full V-Path70.9 mm
T=25mmBACKWALLPZTFULL SKIP (70.9mm)1/2 SKIP (35.5mm)
Ready to model complex Phased Array probes, wedges & weld bevels?Full CAD Studio

Launch the full NDT Setup Builder to compute focal law delays across 16–64 element arrays, simulate curved pipe OD/ID refraction, and export .law and .ondt files.

Open NDT Setup Builder

Governing Acoustic Refraction Formula

Ultrasonic waves travelling from the wedge (medium 1) into the test piece (medium 2) refract according to Snell's Law of acoustic refraction:

sin⁡θ1V1=sin⁡θ2LV2L=sin⁡θ2SV2S\frac{\sin \theta_1}{V_1} = \frac{\sin \theta_{2L}}{V_{2L}} = \frac{\sin \theta_{2S}}{V_{2S}}

Skip Distance & V-Path Geometry

For a plate of thickness TT and refracted angle θ2\theta_2, the half-skip and full skip sound paths are calculated as:

Half Skip=T⋅tan⁡(θ2)andFull Skip=2⋅T⋅tan⁡(θ2)\text{Half Skip} = T \cdot \tan(\theta_2) \quad \text{and} \quad \text{Full Skip} = 2 \cdot T \cdot \tan(\theta_2)
AI-Assisted Technical Reference & Regulatory DisclaimerReference Onlyℹ️ ASME Section V Article 4 & ISO 16810 Non-Destructive Testing

Technical guides, CAD geometries, code calculators, and flaw criteria are engineered in accordance with active industry standards (ASME BPVC, API, AWS, ISO) under ASNT / ISO 9712 Level III engineering guidance for preliminary technical evaluation. This does not replace certified Level III, Professional Engineer (PE), or API 510/570/653 field sign-offs. Always verify specific job parameters against governing client specifications and active code editions before field execution.

All product, brand, and company names (e.g. Olympus, Evident, OmniScan, Sonatest, WAVE, Veo, Eddyfi, Gekko, Mantis, Waygate Technologies, Krautkrämer, Mentor UT, Zetec, UltraVision, BeamTool, Eclipse Scientific, ASME, API, AWS, ISO) are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with, sponsorship, or endorsement by them. All brand and format references are used strictly in a nominative capacity to identify hardware compatibility, scan plan data interchange, and engineering standards compliance.