Heat Exchangers • TEMA RCB-2.3ASME Section VIII Div 1

TEMA RCB-2.3 Heat Exchanger U-Tube Bend Thinning & Cut Length Calculator

Calculate extrados wall thinning percentage, developed cut lengths, cold-forming stress relief heat treatment thresholds (R<5doR < 5d_o), and export multi-row procurement schedule tables.

Presets:
Alloy:
1. Geometric & Forming Parameters (TEMA RCB-2.3)ASME Sec VIII
Tubesheet face to tangent line
Centerline radius to bend axis
Nominal outside diameter
Before cold-bending
PWHT Required: R < 5·do. ASME Sec VIII Div 1 mandates stress-relief heat treatment for cold-bent U-tubes in tight rows.
2. Extrados Wall & Thinning DossierPWHT MANDATORY
Extrados Wall After Bending
1.55 mm
Thinning Percentage:6.0%
Developed Cut Length
6235.6 mm
Weight per Tube
4.42 kg

TEMA RCB-2.31 Extrados Thinning Equation

Thinning of the outer tube wall during cold bending is calculated per:

textrados=tnom⋅(1−do4R+2do)t_{\text{extrados}} = t_{\text{nom}} \cdot \left(1 - \frac{d_o}{4R + 2d_o}\right)

ASME Mandatory Stress Relief Threshold

When centerline bend radius R<5⋅doR < 5 \cdot d_o, cold work strain exceeds threshold limits, mandating post-bending heat treatment (PWHT) per ASME Section VIII Div 1.

AI-Assisted Technical Reference & Regulatory DisclaimerReference Onlyℹ️ Tubular Exchanger Manufacturers Association (TEMA) 10th Edition & ASME BPVC Sec VIII

Technical guides, CAD geometries, code calculators, and flaw criteria are engineered in accordance with active industry standards (ASME BPVC, API, AWS, ISO) under ASNT / ISO 9712 Level III engineering guidance for preliminary technical evaluation. This does not replace certified Level III, Professional Engineer (PE), or API 510/570/653 field sign-offs. Always verify specific job parameters against governing client specifications and active code editions before field execution.

All product, brand, and company names (e.g. Olympus, Evident, OmniScan, Sonatest, WAVE, Veo, Eddyfi, Gekko, Mantis, Waygate Technologies, Krautkrämer, Mentor UT, Zetec, UltraVision, BeamTool, Eclipse Scientific, ASME, API, AWS, ISO) are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with, sponsorship, or endorsement by them. All brand and format references are used strictly in a nominative capacity to identify hardware compatibility, scan plan data interchange, and engineering standards compliance.