MFL Storage Tank Bottom Floor Plate Scanning Guide
Field Procedure for API 653 Annex G & EEMUA 159 Underside Corrosion Sizing
Key Technical Takeaways & Execution Rules
- Magnetic saturation of 6mm to 12mm carbon steel floor plates requires high-strength neodymium permanent magnet bridges generating >=1.8 Tesla.
- Hall effect sensor arrays discriminate top-side corrosion from soil-side underside corrosion using complementary eddy current or surface lift-off sensors.
- Perform dynamic velocity calibration across a reference plate with 20%, 40%, 60%, and 80% machined flat bottom holes under identical scanner drive speed.
- Critical Zone (within 75mm of tank shell corner weld) and Annular Ring require supplementary manual ultrasonic (UT) or high-resolution hand scanner verification.
Step-by-Step Field Execution Procedure
Surface Cleaning & Descaling Verification
Verify floor plates are cleaned to SSPC-SP 6 / NACE No. 3 commercial blast or clean vacuum finish. Remove residual sludge and heavy scale that cause sensor bounce.
Reference Plate Magnetization & Speed Calibration
Drive the MFL scanner across an API 653 reference plate of identical thickness and coating. Calibrate detection thresholds for 20% and 40% underside flat-bottom pits.
Systematic Floor Plate Raster Scanning
Execute lane-by-lane scanning with a minimum 25mm track overlap. Record real-time flux leakage telemetry, distinguishing through-wall indications from soil-side galvanic pitting.
Annular Ring & Inaccessible Edge Interrogation
Utilize motorized miniature edge crawlers or manual 0° UT thickness probes to inspect the 75mm to 100mm dead-zone along the tank shell-to-bottom fillet weld.
Parametric Tank Floor CAD Defect Pinning & MRT Solver
Transfer coordinates directly to API 650/653 Tank Designer CAD. Compute Minimum Remaining Thickness (MRT) per API 653 Section 4.4 and schedule bottom plate patch repairs.
Governing Physical & Code Formulas
API 653 Minimum Remaining Floor Thickness (MRT)
Code FormulaCalculates remaining floor steel at the next internal inspection interval considering top-side and bottom-side corrosion rates.
Probe & Wedge Selection Specs
- Silverwing Floormap / High-Resolution MFL
- Handscan Miniature MFL Crawler
- Dual-Element 0° Ultrasonic Transducer
Code Acceptance Criteria
API 653 Section 4.4.7: Floor plate thickness must not fall below MRT = 0.10 in (2.5mm) for tanks without bottom lining, or 0.05 in (1.3mm) for lined floors before the next scheduled inspection.