10 min read•API 570 Appendix D / ASME Boiler and Pressure Vessel Code Section V Article 4
SRUT / GW • Corrosion ScreeningTarget: Advanced NDT Specialists, Plant Integrity Engineers, API 570/653 Inspectors

Short-Range Ultrasonic Testing (SRUT) Pipe Support & Chime Guide

Field Procedure for Inaccessible Interfaces per API 570 & API 653 Touch Point Inspection

Applicable Standards:API 570 App DAPI 653 Sec 4ASME Sec V Art 4NACE SP0198

Key Technical Takeaways & Execution Rules

  • SRUT interrogates inaccessible metal up to 1000mm (39 in) ahead of the transducer using high-frequency guided shear and creeping waves.
  • Ideal for inspecting touch point corrosion (TPC) under clamped saddle supports, resting pipe shoes, and tank bottom plates extending beneath the shell.
  • Calibrate wave attenuation and reflection on a mockup plate containing machined notches at 10%, 20%, and 40% depth.
  • Signals reflect from both geometric plate edges and corrosion wall loss. Distinguish corrosion reflections by their diffuse, wide phase profile.

Step-by-Step Field Execution Procedure

1

Transducer Wedge Coupling on Bare Accessible Zone

Clean an accessible 150mm strip adjacent to the pipe support or tank chime. Couple a 2.0 to 2.25 MHz broadband angled creeping wave transducer.

2

Wave Velocity Calibration on Mockup Standard

Calibrate guided wave velocity and determine boundary reflection arrival times on a calibration plate representing identical wall thickness and support geometry.

3

Forward Acoustic Projection Beneath Support Pad

Project ultrasonic beam forward underneath the inaccessible support. Monitor the time-of-flight window corresponding to the support footprint.

4

Wall Loss & Notch Echo Discrimination

Analyze returned A-scan signals. Symmetrical sharp reflections indicate the far boundary; intermediate broadened peaks indicate localized galvanic pitting.

5

Repair Triage & Piping Designer Isometric Pinning

Flag support locations exhibiting >30% estimated wall loss. Log coordinates onto ASME B31.3 Piping Isometric CAD for crane lifting and sleeve pad welding.

Probe & Wedge Selection Specs

  • SRUT Creeping Wave Dual Probe
  • High-Frequency Guided Wave Array

Code Acceptance Criteria

API 570 / API 653: Wall loss exceeding 25% of nominal thickness triggers mandatory mechanical lifting or ultrasonic prove-up for remaining wall verification.

Apply This Technique in the Field

Rent Calibrated Hardware or Hire Certified Inspectors