Refinery Reactors, Distillation Columns & Pressure Vessels
Refinery Reactors, Distillation Columns & Pressure Vessels
ASME Sec VIII / API 510 Pressure Vessel Turnaround Scope
Internal Visual, Automated PAUT Corrosion Mapping & Nozzle Weld Verification
Primary NDT Techniques:PAUTTOFDVT
Targeted Damage Mechanisms
- Hydrogen-Induced Cracking (HIC)
- Wet H2S Stress Corrosion Cracking
- High Temperature Hydrogen Attack (HTHA)
- Internal Erosion-Corrosion
Key Inspection Challenges Resolved
- Tight multi-trade turnaround window where scaffolding, internal cleaning, and NDT must coordinate flawlessly.
- Critical nozzle-to-shell welds present compound saddle geometries requiring specialized phased array wedges.
- Wet H2S and sour crude service require high-sensitivity detection of sub-surface micro-cracks.
Standard Field Inspection Workflow
1
Permit & Internal VT Screening
Verify zero-energy de-inventory and perform comprehensive internal direct and remote visual inspection (VT/RVI) of vessel trays, demister pads, and shell lining.
2
Automated PAUT Shell Corrosion Mapping
Deploy magnetic wheel scanner with multi-element phased array probe to map 100% of high-wear shell impingement zones and bottom liquid head.
3
Nozzle & Circumferential Weld Sizing
Execute TOFD/PAUT scans on longitudinal and circumferential Category A & B welds and nozzle attachment welds per ASME Sec VIII UW-51.
4
Wet H2S Fluorescent MT (WFMT)
Perform AC yoke wet fluorescent magnetic particle inspection on internal cladding and nozzle heat-affected zones (HAZ) to detect hydrogen blistering or sulfide stress cracking.
Recommended Hardware & Probes
- Olympus OmniScan X3 64-Channel PAUT Unit
- MagMan Magnetic Wheel Scanner
- Parker B100 AC Yoke
Governing Inspection Standards
- API 510 Pressure Vessel Inspection Code
- ASME BPVC Sec VIII Div 1 & 2
- NACE MR0175 / ISO 15156 Sour Service
Turnaround Operations & Site Prep
Typical Outage Duration:3–6 Turnaround Shifts
Recommended Crew Roster:1× API 510 Certified Inspector, 2× PAUT/TOFD Level II Technicians, 1× MT/PT Technician
Pre-Requisite Site Prep & Safety:
- Internal surfaces chemical washed and free of pyrophoric scale
- Confined space entry permit and continuous ventilation active
- Internal lighting and 110V ground-fault power delivered inside vessel
Certified Deliverables & Sign-Offs
- Full Shell 0° PAUT Corrosion C-Scan Thickness Matrix
- TOFD/PAUT Flaw Characterization & Fracture Mechanics Table
- Internal Visual & Tray Hardware Inspection Logbook
- API 510 Certified MAWP Re-Rating and Inspection Interval Document
Ready to Execute This Scope?