Internal Rotary Inspection System
🐘 Tusker VaultSpecializedUltrasonic • IRIS

Internal Rotary Inspection System (IRIS)

Method Overview

Precision ultrasonic immersion testing technique for scanning the internal and external wall integrity of heat exchanger tubes.

Core Method Specifications

Technique IDIRIS
AcronymIRIS
CategorySpecialized
ModalityUltrasonic
Standardized Report TemplateISO 17020 Ready
IRIS-Standard-TemplateTest in Sandbox

Target Applications & Governing Standards

1 Scopes Configured
Heat Exchangers & Boilers
ASME Sec V Art 4
Target Assets / Components:
Ferrous & Non-Ferrous Heat Exchanger Tubes
Detectable Defects & Anomalies:
• Internal Wall Thinning• Outer Diameter Erosion• Pitting Sizing

Method Limitations & Operational Boundary Conditions

Critical physics limits, thermal envelopes, blind spots, and ASME Sec V / API procedural boundaries for IRIS.

Level III Procedure Control
Operating Temp Envelope
Standard Envelope5°C to +45°C (41°F to 113°F) immersion water temperature
High-Temp CapabilityStrictly limited below 50°C (122°F); elevated water temperatures depolarize the ultrasonic transducer

Water couplant temperature shifts ultrasonic velocity (1480 m/s at 20°C); thermal velocity drift must be calibrated.

Thickness & Dead Zone
Min Thickness0.8 mm (0.032 in) minimum wall thickness
Max RangeTube internal diameter (ID) range from 12 mm to 76 mm (0.5 to 3.0 in); wall thickness up to 8.0 mm
Near-Surface Dead Zone

Ultrasonic ringdown creates a dead zone in the first 0.5 mm of internal wall

Surface Condition & Couplant
Roughness & PrepInternal tube bore MUST be thoroughly cleaned to bare metal (hydro-lanced at 10,000–20,000 psi)
Coating ToleranceInternal coatings or scale absorb ultrasound and disrupt the turbine mirror reflection; tubes must be uncoated
Couplant / Media

Continuous filtered clean water supply delivered at 30–50 psi to drive turbine and flood tube bore

Geometry & Orientation
Orientation Sensitivity

High-speed rotating 45° mirror spins ultrasound beam 360° around tube bore, providing total circumferential wall measurement

Clearance:Open tubesheet channel head clearance for probe insertion and continuous water umbilical hose
Critical Blind Spots
  • •U-bends: Cannot inspect the bend portion of U-tube heat exchangers
  • •Severe internal pitting with sharp angles that scatter ultrasonic sound away from the rotating mirror
  • •Air bubbles in water supply line causing complete loss of ultrasonic backwall signal
False Indication Trap:

Off-centering of the probe centralizer carriage causing distorted elliptical thickness readings

Recommended Cross-Validation

Rapid 10-second pre-screening of entire bundle to identify leaking or plugged tubes prior to IRIS cleaning

Fast electromagnetic screening of carbon steel fin-fan cooler tubes

Level III Code Compliance Directive:ASME Section V Article 4 mandates calibrating rotation speed and axial pull rate (typically 50–100 mm/sec) against an ASME standard EDM notched tube.

Technique-to-OEM Compatibility Matrix

Verified manufacturers, instrument models, and diagnostic portals supporting IRIS.

3 Verified OEMs
Evident Scientific

Evident Scientific

Global leader in advanced optical, ultrasonic, and radiographic inspection technologies (formerly Olympus Scientific Solutions).

Modalities:UTPAUTETVTRVI+3 more
Eddyfi Technologies

Eddyfi Technologies

Advanced non-destructive testing conglomerate encompassing Eddyfi electromagnetic arrays, Silverwing tank floor scanners, Teletest guided waves, Inuktun robotic crawlers, and M2M phased array instruments.

Modalities:ETMFLPAUTACFMPEC+6 more

Waygate Technologies

OEM Manufacturer for IRIS inspection systems.

Verified Partner
ASME Sec V & ISO 9712 Qualified