Optical Gas Imaging (Fugitive Emissions)
🐘 Tusker VidyāAdvancedSurface & Visual • OGI

Optical Gas Imaging (Fugitive Emissions) (OGI)

3D MESHIntegrated Engineering Studio

Drone 3D Mesh & Defect Locator

3D photogrammetry defect pin locator with coordinate tracking.

Launch Studio

Method Overview

Specialized spectral narrow-band infrared thermography (3.2–3.4 µm) tuned to the absorption bands of VOCs and hydrocarbons. Visually reveals invisible methane, propane, benzene, and greenhouse gas leaks in real-time under EPA LDAR regulations.

Core Method Specifications

Technique IDOGI
AcronymOGI
CategoryAdvanced
ModalitySurface & Visual
Standardized Report TemplateISO 17020 Ready
OGI-Standard-TemplateTest in Sandbox

Target Applications & Governing Standards

1 Scopes Configured
Storage Tanks
EPA Method 21 EPA 40 CFR Part 60 Subpart OOOOa/b EN 15446
Target Assets / Components:
Storage Tank Thief HatchesCompressor Station SealsFlange ConnectionsPressure Relief Valves (PRV)
Detectable Defects & Anomalies:
• Fugitive Methane Emissions• VOC Atmospheric Vents• Valve Packing Leaks

Method Limitations & Operational Boundary Conditions

Critical physics limits, thermal envelopes, blind spots, and ASME Sec V / API procedural boundaries for OGI.

Level III Procedure Control
Operating Temp Envelope
Standard Envelope-20°C to +50°C (-4°F to 122°F)
High-Temp CapabilityHigh background thermal scenes up to 350°C (662°F)

Requires a minimum apparent temperature difference (ΔT ≥ 2°C) between leaking gas plume and background scene for contrast.

Thickness & Dead Zone
Min ThicknessN/A (Optical atmospheric line-of-sight imaging)
Max RangeObservation range from 0.5 m up to 100 m depending on lens focal length and wind conditions
Near-Surface Dead Zone

Gas plumes closer than 0.3 m require wide-angle macro optics

Surface Condition & Couplant
Roughness & PrepN/A; evaluates volatile gas phase plumes escaping from component boundaries
Coating ToleranceFully unaffected by surface coating or insulation
Couplant / Media

None

Geometry & Orientation
Orientation Sensitivity

Survey from downwind direction to observe plume rising against cooler sky or uniform thermal background

Clearance:Standoff inspection enables surveying elevated racks and flare lines from ground level
Critical Blind Spots
  • •High wind velocities (> 25 km/h / 15 mph) rapidly dissipate gas plumes below camera detection limits
  • •Zero thermal contrast (ΔT = 0°C) when gas plume matches background temperature exactly
False Indication Trap:

Solar glint and thermal reflections off cylindrical pipe surfaces mimicking escaping VOC gas clouds

Recommended Cross-Validation

Quantify mass leak rate using calibrated bagging or toxic vapor sniffer per EPA Method 21

Verify pipe wall thickness near leaking steam or hydrocarbon valves

Level III Code Compliance Directive:EPA 40 CFR Part 60 Subpart OOOOa mandates daily response factor verification with calibration gas before beginning LDAR surveys.

Technique-to-OEM Compatibility Matrix

Verified manufacturers, instrument models, and diagnostic portals supporting OGI.

3 Verified OEMs
Teledyne FLIR (GasFindIR)

Teledyne FLIR (GasFindIR)

Pioneer of Optical Gas Imaging (OGI) infrared cameras for visualizing fugitive hydrocarbon, methane, VOC emissions, and SF6 electrical gas leaks under EPA OOOOa/b LDAR regulations.

Modalities:OGIIRTLDAR

Opgal EyeCGas

OEM Manufacturer for OGI inspection systems.

Verified Partner

Sierra Olympic

OEM Manufacturer for OGI inspection systems.

Verified Partner
ASME Sec V & ISO 9712 Qualified